one. Electronic barcode scale 41 setting
First enter the Z mode (press [Mode] four times in the weighing state until Z1.0 appears on the screen) Press Zero +141
Step 1: 0X4, press [Print]: (Set barcode format, standard format: F1F2CCCCCXXXXXCD)
Step 2: Press [Print] on 3X28: (Set the leading position of the barcode, such as 28)
The third step: 24X16 press [Print]: (Set the label format, standard format: F1)
Step 4: 41X0 press [Print]: (Automatic conversion of weighing and non-weighing)
Step 5: Press [Print] on 42X0: (The price can be changed after the PLU code is called)
Step 6: 49X2 Press [Print]: (Do network settings)
Step 7: 50X1 press [Print]: (Do network settings)
Step 8: 64X1 press [Print]: (Prohibit setting password)
Step 9: 135X, press [Print]: (Set the scale: the fourth digit of the IP address) [The first three IP settings refer to the third step]
Press [#] to save, then press [Mode] to return to weighing.
Note: The following is a method for switching each mode to each other. The following settings will not be described again:
S mode: Press [Mode] three times in the weighing state until S1.0 PLU FILE appears on the screen:
Z mode: Press the [Mode] key four times in the weighing state until Z1.0RESET SALES appears on the screen:
two. Electronic barcode scale 142 setting
Enter Z mode; press zero +3752, then press to set zero +142, 629X4 (total amount of digits rounded off), press [print]; 646X1 (when the weight is less than 40g and the total price is greater than 5 cents can be printed), Press [Print]; then press [#] to save. Press the [Mode] button again.
Shut down (press the switch at the bottom of the machine), then turn it on again.
two. Electronic barcode scale IP address setting (ie the first three digits of IP settings):
Enter the Z mode. Press to set the value of +3752, then press the set zero +0416, then enter the first three digits of the IP address: (for example: 192.168. 0 is entered on the scale), press [#] to save, turn off the power and then turn it on. can.
The last digit of the IP address is the scale: (change its title: zero +141, 135X, enter the corresponding title)
four. Electronic barcode scale editing label free format (*Note: The example is: 35X37 label paper, the actual situation is based on the length and width of the printed label paper)
(1) Enter the label editing mode:
When the electronic barcode scale enters the S mode. Press 12, [Print]; 1, [Print]: Enter the label width (in this example, enter 35), [Print]; enter the label height (in this example, enter 37), [Print]; use [" and [ The ">] key switches the angle of the label (in this example, keeps the default value of 0 degrees), [Print]; press [Print] again; when S12.5PLUno appears, the label editing mode is entered.
(2) Set the label free format (setting of the label item)
Total edit price: Enter 2, [Print] (enter the two settings): Enter the X axis start value: 7, [Print]; Enter the Y axis start value: 1, [Print]: Print angle selection: through the left keyboard Switch the [" and []" keys (in this example, keep the default value of 0 degrees), [Print]; select the print status: Enter 7, [Print]: Select the font: by left-clicking [" and ["] The key switch (in this case, select M4), [Print], the total price one bit setting is completed.
* Description: About the print status:
0: no printing; 3: printing when weighing; 4: non-weighing printing;
7: Print all (printed at any time)
Edit unit price: 3. [Print] (enter three settings): X axis: 0, press [Print]; Y axis: 6, [Print]: Angle selection: switch through the [" and []" keys on the left keyboard (In this example, keep the default value of 0 degrees), [Print]: Select the print status: Enter 7, [Print]: Select the font: Switch between [" and []" on the left keyboard (in this case select S5), [Print ].
Edit weight: 4, [Print] (enter four settings): X axis: 0, press [Print]: Y axis: 1, [Print]: Angle selection: Switch by [[] and [ ">] keys on the left keyboard (In this example, keep the default value of 0 degrees), [Print]: Select the print status: Input 3, [Print]: Select the font: Switch between [" and []" on the left keyboard (in this case, select S5), [Print ].
Number of edits: 5, [Print] (enter five settings): X-axis: 2, press [Print]: Y-axis: 1, [Print]: Angle selection: Switch via the [" and []" keys on the left keyboard (In this example, keep the default value of 0 degrees), [Print]: Select the print status: Enter 4, [Print]: Select the font: Switch between [" and []" on the left keyboard (in this case, select S5), [Print ].
Edit packaging date: 6, [Print] (enter six settings): X axis: 10, press [Print]: Y axis: 6, [Print]: Angle selection: through the [" and []] keys on the left keyboard Switch (in this example, keep the default value of 0 degrees), [Print]: Select the print status: Enter 7, [Print]: Select the font: Switch between [" and ["] on the left keyboard (in this case, select S5), [ print].
Edit product name: 8, [Print] (enter eight settings): X axis: 0, press [Print]: Y axis: 21, [Print]: Angle selection: through the [" and []] keys on the left keyboard Switch, [Print]: Enter the print width of the product name: (in this example, enter 34), [Print]: Enter the print height of the product name: (in this example, enter 6), [Print]; select Print Off: Enter 7, [print].
Edit shelf life: 10, [Print] (enter ten settings): X axis: 17, press [Print]: Y axis: 6, [Print]: Angle selection: switch through the [" and []" keys on the left keyboard (In this example, keep the default value of 0 degrees), [Print]: Select the print status: Enter 7, [Print]: Select the font: Switch between [" and []" on the left keyboard (in this case select S5), [Print ].
Edit barcode: 12, [Print] (enter twelve settings): X axis: 2, press [Print]: Y axis: 11, [Print]: Angle selection: through the [" and []] keys on the left keyboard Switch [Print]: Enter the barcode height: (in this example, enter 9), [Print]: Select the print status: Enter 7, [Print].
Edit shop name: (This item is generally not set, because the label has been brushed): 13, (Enter 13 settings): X axis: 2, press [Print]: Y axis: 31, [Print]: Angle selection: Use the [" and [ ]" keys on the left keyboard to switch [Print]: Enter the store name width: (in this example, enter 30), [Print]: Enter the print height of the store name: (in this example, enter 6), [Print] : Select the print status: Enter 7, [Print].
Finally press [#] to save, then press [Mode] to exit.
* Description:
1, font (there are two) 1S1-55; 22M1-M5
If you modify the items; you should first enter the S mode. Press 12[Print]: 1, [Print]: Enter the label width, [Print]: Enter the label height, [Print]; use the [" and []" keys to switch the angle of the label (in this example, keep the default value of 0 degrees) ), [Print]: Press [Print] again. When S12.5 PLUno appears, it enters the label editing mode. Then press the corresponding item to edit: (eg: 2[Print, modify the total price setting]) Finally press [#] to save.
Fives. Electronic barcode scale input (edit) product name, unit price, barcode, shelf life, packaging date:
Enter S mode. Press [Print], enter the product number, press [Print]; enter the unit price, press [Print]; then press Print: Enter the product name (Location code input method, select the font: switch through the 36 keys on the left keyboard) Font size, generally choose G4) Press [Print]: Press [Press] again; enter the corresponding barcode, press [Print]; press [X] to select whether to print the shelf life (NPRINT is not printed; PRINT is printing, generally Select PRINT), press [Print]; enter the expiration date, press [Print]; press [X] to select whether to print the packaging date (NPRINT is not printed. PRINT is generally selected); finally press Save [#], then Press [Mode] to exit.
six. Electronic barcode scale preset button (shortcut key): (Shanghai Zhishuo Co., Ltd. http://)
Enter S mode. Press 4, [Print] to enter the product number, press the corresponding button on the left button; when you make the next product preset button, you can directly press the input product number, press the corresponding button on the left keyboard, and repeat accordingly. After completing the preset button, press [Method]; [Clear], [Mode] to exit.
Seven. Electronic bar code scale to do calibration: (put weight: the maximum weight of the scale)
Enter the Z mode. Press to set the value to +3752, release the button and set the value to +8715. When CAL00 is displayed, press [Print]; when the CALP is displayed, put the code (15kg), press [Print]; wait... until the screen appears again Z1.0 Press [Mode] to exit and remove the weight.
Eight. Adjust the position of the detection line of the electronic bar code scale (ie: the detection line position printed after pressing the [Feed] button, that is, the 0 starting point of the label Y axis):
Enter the Z mode. Press to set zero +514, then enter the number of positions: can be positive or negative, positive up, negative down (negative number: first enter the number, then press [-] key), press [#] to save, Then press the [Feed] button (press twice more) to test.
nine. Clearing of electronic barcode scale data:
(1) Clear PLU (ie all product data): Enter Z mode, press [Zero] + 230, and when the screen displays CLEAR PLU FILE, press [Print]. Press [Erase] at this time to clear all PLUs in the scale; press [Tare] to not operate.
(2) Clear memory (ie clear all data in memory, package according to label format): Enter Z mode, press [Zero] + 230, when CLEAR PLU FILE is displayed on the screen, press [≈] on the left keyboard preset button three times. Press the key until CLEAR MEMORY DATA appears on the screen, press [Print], then press [Clear] to clear all data in the scale: press [Tare] to not operate.
ten. Scale:
(1) Weighing the product: Put the product, enter the product number (that is, the PLU code of the product), press the [#] button, and press [Print].
(2) For non-weighing goods (no need to put the goods, count the number of copies), enter the product number (PLU code), press [#], press [X], enter the sales quantity, press [Print] If you only print one item, press [#] and then press [Print].
*Note: If you press the left keyboard preset button to scale, you can omit the [#] key.
Eleven. Automatic printing
(1) Automatic printing of weighing goods: First enter the automatic state (ie press [Auto] in weighing mode, the cursor on the screen points to P). Enter the item number (ie PLU code), press [#] to put the item, the label will be printed automatically after stabilization; the next step can be repeated by printing the next label; to terminate the printing, just click [ Auto] button.
(2) Automatic printing of non-weighing goods: Enter automatic status. Enter the item number (ie PLU code) and press [#], press [Print], enter the number of labels to be printed, press [Print], then the next sheet The label is automatically printed after it is taken away, until the number entered is printed. If you want to terminate the print, just press the [Auto] button.
*Description: The cursor on the screen (green triangle) points to M as the manual state, that is, the state normally used for weighing the scale: pointing to P is the automatic state, that is, the automatic state, press [Auto] to switch back and forth, if no automatic printing is required The cursor needs to be positioned in the manual state.

Radial Artery Compression Devices

Radial artery compression devices, also known as radial artery compression devices or wristbands, are used to achieve hemostasis after a transradial cardiac catheterization procedure. The device is applied to the wrist and inflated to compress the radial artery, which is the artery that supplies blood to the hand and fingers. This compression helps to prevent bleeding and hematoma formation at the site of the catheterization.
Radial artery compression devices are preferred over traditional compression methods such as manual compression because they are more effective, comfortable for the patient, and allow for earlier ambulation and discharge. They also reduce the risk of complications such as radial artery occlusion and nerve injury.
In addition to cardiac catheterization procedures, radial artery compression devices may also be used after other procedures that involve the radial artery, such as transradial access for arterial blood gas analysis or for the placement of intra-arterial lines.

Radial Artery Compression Devices,Outlet Radial Artery Compression Device,Disposable Radial Artery Compression Device,Medical Consumables Tourniquet

Changzhou Weipu Medical Devices Co., Ltd. , https://www.cnweipumedical.com

Posted on