After the farmers bought the pump, how can they be used properly to make the most of the pump? If the use is unreasonable, the service life of the pump will be shortened. Therefore, proper use of the method is an important factor in prolonging the life of the pump and reducing the economic loss.

First, for the submersible pump, some necessary checks should be done before start-up: whether the rotation of the pump shaft is normal, whether there is stuck phenomenon; whether the position of the impeller is normal; whether the cable wire and the cable plug have cracked, scratched and broken, etc. . During the operation, attention should be paid to observe the change of the voltage, generally within 5% of the rated voltage. In addition, the location of the pump in the water is very important. It should be possible to choose a place where there is plenty of water, no silt, and good water quality. It should be suspended vertically in the water. It must not be placed horizontally so as to avoid being trapped in the mud or blocked by the suspended material. Lead to a sharp drop in the amount of water or even no access to water.

Second, for the self-priming pump, it should be placed in a well-ventilated place to run as much as possible to facilitate rapid heat dissipation and reduce the motor temperature. Otherwise, long-term operation can easily burn the motor. For example, when a farmer uses a self-priming pump, it does not remove the plastic film covering the motor, causing the motor to overheat and burn out the coil. In addition, before starting, be sure to check the amount of water in the pump body, otherwise, not only affect the self-priming performance, but also easy to burn the shaft seal components. Under normal conditions, the water should be discharged within 3 to 5 minutes after the pump starts. Otherwise, it should be stopped immediately.

Third, when the pump fails, do not remove yourself. Because of their own demolition, first, they do not know where the fault caused blindly dismantling a pass; Second, there is no special tools and often damage the original spare parts. The best way is to go to an experienced and large-scale maintenance point repair and replace “overage” parts and certain wearing parts in time. Under normal circumstances, the pump should be repaired every six months to eliminate "disease" work.

Fourth, in the non-use period, the pump should be promptly lifted from the water source, and drain water in the pump, especially in the cold winter. Then place it in a dry place. Conditional users can also apply grease to the key parts of the pump and add lubricant to the bearings to prevent corrosion of the parts. In addition, the non-use period of the pump is not as long as possible. If you do not use it for a long time, it will not only easily rust parts, but also reduce the service life of the pump.

Ecg Holter Monitor  is a device for checking ECG, which is applicable for family and individual user, it is a good helper to early prevent from cardiovascular diseases and reduce risks. Intelligent design, achieves remote health management by using with mobile application, it can automatically start measurement, store ECG, upload data, download health conclusion and obtain doctor advice at the first moment. 